In case your thermostat cables connect with terminals marked Th, Tr, and Th-Tr, they’re likely connecting to a gasoline valve.

Nonetheless, you will have to locate the cables linking into the fuel valve and follow them into the transformer that is 24VAC the heating gear to determine where your “C” connection will soon be. In the event that you need help with this, be sure to contact ecobee help.

Merely link the free cable to your typical connection point.

IF YOU’VE GOT NO ADDITIONAL WIRES

Should you not have any additional wires, you have got two choices:

    • Run a wire that is additional your thermoregulator down to your gear

  • Buy and install a Fast-Stat Common Maker

ALTERNATE SOLUTION: 24VAC TRANSFORMER that is PLUG-IN

Another solution would be to power the ecobee having an outside plug-in transformer that is 24VAC.

This transformer could be attached to a wall surface, and will be wired the following:

  • The 24VAC transformer cables would hook up to RC and C in the ecobee
  • The 2 cables in your old thermostat would connect with RH and W1 regarding the ecobee

NOTE: make sure the transformer is with the capacity of 24V AC production ( perhaps perhaps not DC production)

Scenario C:MY THERMOSTAT LINKS TO T/T TERMINALS

In case your thermostat cables connect with T/T terminals, keep in mind that you’ll need an independent transformer that is 24VAC power the ecobee. You can also need components that are additional.

T/T connections frequently suggest an association to a computer device referred to as an Aquastat.

IF AN EXTRA is had by you CABLE

When you have an additional cable, you’ll need an isolation relay and an independent 24VAC transformer.

ecobee calls for an isolation relay having a 24vac coil and Normally Open (N/O) connections.

IF NO EXTRA is had by you WIRES

For those who have no additional cables, you will need both a Fast-Stat Common Maker and an independent transformer that is 24VAC

ALTERNATE SOLUTION: 24VAC TRANSFORMER that is PLUG-IN

Another solution would be to power the ecobee having a outside plug-in transformer that is 24VAC.

This transformer could be connected to a wall, and could be wired the following:

  • The transformer that is 24VAC would hook up to RC and C in the ecobee
  • The 2 cables on your own old thermostat would connect with RH and W1 from the ecobee

NOTE: Ensure the transformer is with the capacity of 24V AC production ( perhaps maybe not DC production)

NOTE (2): Some T/T connections might not work reliably whenever linked straight to the Rh and W1 terminals of this ecobee. A 24 VAC transformer and isolation relay on the equipment side would be necessary (see details under “IF YOU HAVE AN EXTRA WIRE” above) in that case.

For those who have a couple of thermostats managing your heat:

If for example the heat is managed by a lot more than one thermoregulator, the body most likely has area valves or an area control relay.

Please touch base to ecobee help because of the information that is following purchase to find out compatibility and appropriate installation directions:

  • Just exactly exactly How thermostats that are many have actually as a whole for the home heating
  • Photos associated with wiring at each thermostat
  • Photos of this wiring at any area valves or zone panels
  • The make and model of each and every area valve and/or area panels
  • The amount of additional cables which are behind the wall surface at each thermostat

Some commonly used brand names for zone valves/zone control equipment include if you are having difficulty identifying your zone valves or zone boards

  • Taco
  • Honeywell
  • Erie
  • Energy Kinetics

As an Amazon Associate, ecobee earns from qualifying acquisitions

About the author

sigal